Fujitsu 3.50kW Cooling 4.50kW Heating Floor Console

Agtg14kvca   fujitsu 4.20kw cooling 5.20kw heating floor console
Agtg14kvca   fujitsu 4.20kw cooling 5.20kw heating floor console
AGTG12KVCA
$2,998
Afterpay 4 payments from $749.50
Wishlist
Fujitsu

Fujitsu 3.50kW Cooling 4.50kW Heating Floor Console

AGTG12KVCA

10°C Heat Operation
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

All DC
With All DC, electricity loss is decreased and power consumption reduced.

Apple-Catechin Filter
Fine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.

Auto Restart
Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

Auto Shut Louvre
The auto shut louvres close or open automatically when the unit stops or starts.

Auto Changeover
The unit automatically switches between operating modes based on the temperature setting and room temperature.

Automatic Air Flow Adjustment
The micro-processor automatically adjusts the air flow to follow changes in room temperature.

Automatic Louvre
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

Economy Mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.

Long-Life Ion Deodorisation Filter
The filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.

On-Off Timer
ON-OFF timer can be set to operate once every 24 hours.

Powerful Mode
Powerful mode will operate the indoor unit fan and outdoor unit compressor at maximum operation to quickly make the room conditioned and comfortable.

Program Timer
This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

Sleep Timer
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

Super Quiet Mode
The indoor units fan can operate at a low speed to produce quieter operation.

Up/Down Swing Louvre
The up/down louvre automatically swings up and down.

V-PAM
v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

Washable Panel
Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.

Weekly Timer
Different ON-OFF times can be set for up to 7 days.

0.5°C Increments
The remote control now allows you to set temperature in 0.5°C increments, giving you a better control on your comfort.

Gas(Refrigerant) detector
For user additional safety measures, the indoor unit is equipped with a refrigerant leak detection sensor.

Outdoor Unit Low Noise Mode
The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.

Properties

Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 3.50 (0.9 - 4.3)
Heating Capacity kW (Rated (Min - Max)) 4.50 (0.9 - 6.1)
Input Power Cooling kW (Rated (Max)) 0.85 (2.12)
Input Power Heating kW (Rated (Max)) 1.11 (2.15)
EER Cooling kW/kW 4.1
COP Heating kW/kW 4.05
Star Rating Cooling (0-10) (Hot / Average / Cold) 4.5 / 4 / 4.5
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2.5 / 2
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 6.373 / 5.898 / 6.224
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.753 / 4.316 / 3.841
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 7.338 / 7.901 / 9.357
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.752 / 4.485 / 4.08
Running Current amps (Cooling / Heating) 4.1 / 4.05
Moisture Removal l/hr 1.8
Indoor Sound Pressure Cooling dBA (High / Quiet) 40 / 22
Indoor Sound Pressure Heating dBA (High / Quiet) 43 / 22
Outdoor Sound Pressure dBA (Cooling / Heating) 44 / 49
Outdoor Sound Power dBA 58
Air Circulation (Indoor - High Fan) Cooling l/sec 158
Air Circulation (Indoor - High Fan) Heating l/sec 181
Indoor Unit Dimensions mm (Height x Width x Depth) 600 x 740 x 200
Indoor Unit Weight kg 14.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 632 x 799 x 290
Outdoor Unit Weight kg 38.00
Piping Connects mm Ř (Liquid / Gas) 6.35 / 9.52
Pipe Length m (Max (Precharged)) 20 (15)
Max Height Difference m 15
Operation Range Cooling °CDB (Min to Max) -10 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R32

This product comes with a 60 month manufacturer's warranty.

In Stock Indicator

This feature is designed as an indicator only. Our stock levels are changing constantly and from time to time stock could go missing, get stolen or become faulty/damaged meaning this may not be 100% accurate. We do however endeavour to keep this as up to date as possible. We recommend calling ahead to your preferred store to confirm before ordering. 

Delivery Time Frames

Please be patient with us. We’ll do our best to get your orders to you as fast as possible however, some orders may be delayed. Orders with multiple items may be delivered as separate packages. Heathcotes are committed to safeguarding the health, safety and wellbeing of our customers, employees and communities and will adhere to the Government’s guidelines when handling these items.

Once you place your order our work begins. Our extensive delivery network means we can ship anywhere in the North & South Islands. We will ship directly to your home or business. Please click here for the latest updates from NZ Post regarding the courier network.

Once the order leaves our warehouse you will receive a dispatch email with tracking information. 

Delivery time frames vary depending on location in New Zealand. Please allow for extra time if you are in a rural address.

Small items Delivery Time Frames - Please allow 5-10 working days. Rural areas please allow an extra day or two.

Large items Delivery Time Frames - Please allow 5-10 working days. Rural areas please allow an extra day or two.

Bed & Bedroom Furniture Delivery Time Frames - Please allow 10-14 working days. Rural areas please allow an extra day or two.

Please note the delivery fee covers delivery only - this does not cover installation.

Additional Delivery Services Terms & Conditions

Appliance Removal
Our team will take your old washing machine away to our local distribution centre when they deliver your new one. Removal must be done at the delivery location of your order and on the same day.

Any appliance to be removed must be disconnected from all water & electrical supplies by you or your contractor in advance of the appliance being removed. You agree that removed goods are deemed to have zero value and become our property. We may dispose of them as we see fit.

Rubbish Removal
Whether we are doing the install or you, we’ll unbox your appliance & remove the packaging from your home. No need to find a home for that polystyrene! We’ll take care of it.

Installation of Washing Machines
On delivery day we’ll carefully move your new washing machine to wherever you want it positioned. We’ll unbox it and, provided you have the necessary electricity connection and plumbing in place, connect the washing machine.

We’ll remove any transit bolts, ensure its levelled and test it for basic operation.

Installation of Dryers
On delivery day we’ll carefully move your dryer to wherever you want it positioned. We’ll unbox it and, provided you have the necessary electricity connection, connect the dryer.

We do not wall mount dryers, install dryer ducting or mount the dryer on a stacking kit. Our installation service is to existing connections only so if ducting is already in place we can connect to it.

Installation of Refrigerators
On delivery day we’ll carefully move your new fridge or freezer to wherever you want it positioned. We’ll unbox it and, provided you have the necessary electricity connection, connect the fridge or freezer to power.

We do not change the hinge on refrigerators, connect to plumbing or install panels on integrated refrigerators as part of this install service.

Tracking Your Order

Heathcotes partner with Courier Post & Fliway Transport to deliver your order direct to your door.

Please note delivery drivers are unable to enter your house.

If you have any questions regarding the delivery of your product please contact the Heathcote Appliances website team website@heathcotes.co.nz

Freight Rates

The easiest way to calculate freight cost when viewing an item is to click the "Calculate Freight" link and then enter your postcode. If you are ordering multiple items, often there will be a freight saving - the total freight cost will be displayed at shopping cart time.
Please note the delivery fee covers delivery only - installation is not included.

National Delivery Network

For smaller orders, we use CourierPost's network, for larger orders we use Fliway's Delivery Network. All orders must be signed for on delivery so we know that your purchase has been delivered successfully.

Contact Us:

If you have any questions regarding the delivery of your product please contact the Heathcote Appliances website team.website@heathcotes.co.nz

Reviews